GOFLEX PUMP

V-025 Rotary Vane Vacuum Pump

The GOFLEX V-025 (VR-025) is a single-stage, oil-sealed rotary vane vacuum pump for industrial vacuum systems. Review the listed specifications for the proposed motor, voltage and frequency. Request pumping-speed curves at your required working pressure when reviewing pump-down time and process flow.

Send the chamber volume, target pressure, gas composition, vapour or particle load and operating schedule. Confirm oil requirements, gas-ballast configuration, inlet protection, exhaust treatment, cooling and maintenance for the proposed installation. Continuous-duty capability, exhaust cleanliness and application suitability should be confirmed for the operating conditions.

Browse all rotary vane vacuum pumps to compare other models.
Send Your Inquiry Now
Side view of a dark gray pump with a rectangular housing and upright metal fitting.

Image Gallery

Top view of a gray pump showing the motor, terminal box and side housing.
Gray vacuum pump with an attached electric motor.
Compact gray rotary vane vacuum pump with an upright hose connector and a vented motor fan cover.

Specification

V025 Single-Stage Rotary Vane Vacuum Pump Technical Specifications
PARAMETER / SPECIFICATIONVALUE / DETAILKEY BENEFIT / DESCRIPTION
ModelV025 / VR-025V-Series rotary vane model
Pumping Speed25 m³/hConfirm the pumping-speed curve at the required inlet pressure and supply frequency.
Ultimate Vacuum0.1 – 0.5 mbarConfirm test conditions and the achievable system pressure under the process gas load.
Motor Power0.75 kWConfirm the selected motor, supply frequency and power requirements.
Nominal Speed2880 rpmConfirm the rated speed and supply frequency for the selected motor.
Allowable Water Vapor Pressure40 mbarConfirm test conditions, permitted vapour load, gas-ballast configuration and oil requirements.
Water Vapor Extraction Capacity0.3 kg/hConfirm inlet temperature, pressure, operating schedule and upstream condensation or separation needs.
Operating Temperature82 ℃Confirm measurement conditions and the permitted temperature range and duty cycle.
Inlet Port SizeG 3/4" ThreadConfirm thread details and mating-pipe dimensions before connection.
Oil Capacity0.5 LConfirm the specified oil grade, filling procedure and maintenance intervals.
Noise Level≤ 62 dB(A)Confirm noise test conditions, mounting and any installation-specific acoustic measures.
Net Weight22 kgPlan handling and lifting using the supplied installation instructions.
Dimensions (L × W × H)330 × 220 × 195 mmConfirm mounting points, ventilation clearances and service access before integration.

Features & Benefits

  • OEM Installation Review:The page lists a 22 kg pump weight. Confirm dimensions, mounting points, ventilation space and service access against the selected configuration before integration.
  • Oil Mist Filtration:Confirm the supplied exhaust oil mist filter and its maintenance requirements. Exhaust quality depends on gas load, oil condition and filter condition; assess ventilation and discharge routing for the installation.
  • Noise & Vibration Conditions:Confirm noise test conditions and mounting requirements for the supplied configuration. Review vibration isolation and fastening against the installation instructions and supporting structure.
  • Continuous-Duty Conditions:Confirm the permitted duty cycle, inlet-pressure range, gas compatibility, ambient conditions and cooling requirements before specifying continuous operation.
  • Maintenance Access:Confirm the oil grade, inspection and replacement intervals, filter servicing and access requirements in the supplied maintenance instructions.

Target Applications & Industry Uses

Primary Industrial Applications

  • Thermoforming & Blister Packaging: For blister forming, skin packaging or tray sealing, size against chamber volume, target pressure, cycle time and leakage. Confirm moisture carryover, inlet protection and exhaust handling.
  • Degassing & Impregnation: For resin deaeration, impregnation or drying, assess gas release, condensable load and required pressure. Confirm oil compatibility, gas-ballast configuration and upstream separation.
  • Vacuum Handling & Automation: For suction cups, fixtures or robotic handling, calculate holding force from pressure differential and effective area. Review leakage, workpiece porosity, cycle time and loss-of-vacuum safeguards.
  • Vacuum Distillation & Injection: For crystallization, cavity evacuation or low-temperature drying, confirm gas composition, vapor load, target pressure and evacuation time; review material compatibility and upstream treatment.

Suitable Machinery & Industries

  • Packaging Machinery: For packaging or food-processing equipment, confirm inlet protection, exhaust routing and process contamination controls as part of the complete machine design.
  • Material Processing: For chemical or resin processing, review gas and condensate compatibility with the pump and oil, including separation and any hazardous-area requirements.
  • Vacuum Systems: For mobile or laboratory distribution systems, assess simultaneous demand, pipeline pressure losses, gas compatibility, ventilation and service access.
  • Automation Equipment: For CNC tables, manipulators or mold vacuum modules, confirm holding or evacuation requirements, leakage, filtration and operating schedule for the specific equipment.

Frequently Asked Questions

The pages list pumping speeds of 25 m³/h for V-025 and 20 m³/h for V-020, both with 0.75 kW motor power. Compare performance curves at the required pressure, supply frequency, chamber volume and system conductance. The listed speed difference does not establish a fixed percentage reduction in evacuation time; confirm mounting dimensions separately.

The page lists water-vapor reference values of 40 mbar and 0.3 kg/h. Confirm their test conditions and the permitted vapor load, gas-ballast configuration, oil and operating temperature for the supplied pump. Review upstream condensation or separation needs; a listed operating temperature alone does not guarantee that condensation is prevented.

Follow the supplied installation instructions for fastening, supporting-surface strength, ventilation and vibration isolation. Confirm mounting points and any isolation pads for the machine frame and operating conditions; the listed 22 kg weight alone does not establish that unanchored operation is suitable.

Ready to Upgrade Your Industrial Vacuum System?

Send the model, target pressure, gas load, electrical supply and operating schedule for a configuration and quotation review. Request drawings and confirm availability and lead time for the proposed configuration.

Copyright © 2026 goflexpump.com. All Rights Reserved
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram