GOFLEX PUMP

VB-1400 Series Oil-Free Piston Vacuum Pumps

The GOFLEX VB-1400 Series offers VB-1400V and VB-1400H oil-free piston vacuum pump configurations. Compare the listed voltage, frequency, airflow and vacuum data for each variant. Select against the flow available at your required working vacuum; maximum airflow and maximum vacuum should not be assumed to occur at the same operating point.

For OEM machinery, laboratory manifolds or packaging equipment, provide the gas composition, operating schedule, ambient conditions and installation space. Confirm motor protection, cooling, connection dimensions, inlet filtration, exhaust arrangements and service requirements for the proposed configuration. Review noise measurement conditions and the accessories included in the quotation. Pharmaceutical or other controlled processes require application-specific compatibility and validation checks.
Send Your Inquiry Now
Silver and black pump with two finned heads connected by a brass-colored tube.

Image Gallery

Front view of a twin-head pump with silver covers and a black center housing.
Silver twin-head pump with black center housing and a connecting tube above.
Compact pump viewed from above, showing two finned heads and a loose power cable.

Specification

VB Series Technical Specifications (Featuring VB-1400 Specifications)

ModelVoltageFreq.PowerCurrentMax VacuumMax FlowPort SizeNoiseWeight
VB-1400V High Airflow110V50 Hz0.51 kW4.6 A-700 mmHg
(-93.3 kPa)
120 L/min1/4" NPT/G56 dB(A)7.85 kg
110V60 Hz0.67 kW5.9 A145 L/min
220V50 Hz0.45 kW1.7 A120 L/min
220V60 Hz0.55 kW2.3 A145 L/min
VB-1400H High Vacuum110V50 Hz0.36 kW3.4 A-740 mmHg
(-98.6 kPa)
92 L/min
110V60 Hz0.44 kW3.9 A105 L/min
220V50 Hz0.40 kW1.6 A95 L/min
220V60 Hz0.50 kW2.1 A110 L/min
VB-400V110V50 Hz0.24 kW2.7 A-680 mmHg50 L/min1/4" NPT/G56 dB(A)6.5 kg
110V60 Hz0.25 kW2.3 A60 L/min
220V50 Hz0.22 kW1.1 A50 L/min7.8 kg
220V60 Hz0.21 kW1.0 A60 L/min
VB-900V / H110V60 Hz (V)0.19 kW1.8 A-685 mmHg95 L/min7.85 kg
220V50 Hz (V)0.17 kW0.8 A-685 mmHg85 L/min
110V60 Hz (H)0.23 kW2.3 A-740 mmHg68 L/min
220V50 Hz (H)0.16 kW0.7 A-740 mmHg60 L/min
VB-1200V / H110V60 Hz (V)0.45 kW4.1 A-700 mmHg125 L/min
220V50 Hz (V)0.24 kW1.5 A-700 mmHg105 L/min
110V60 Hz (H)0.30 kW2.9 A-740 mmHg95 L/min
220V50 Hz (H)0.35 kW1.5 A-740 mmHg85 L/min
VB-1800V / H110V60 Hz (V)0.59 kW5.1 A-700 mmHg185 L/min3/8" NPT/G60 dB(A)11.0 kg
220V50 Hz (V)0.55 kW2.5 A-700 mmHg155 L/min
110V60 Hz (H)0.58 kW5.2 A-740 mmHg135 L/min
220V50 Hz (H)0.55 kW2.5 A-740 mmHg110 L/min
VB-2000V / H110V60 Hz (V)0.60 kW5.3 A-700 mmHg208 L/min
220V50 Hz (V)0.55 kW2.5 A-700 mmHg170 L/min
110V60 Hz (H)0.60 kW5.2 A-740 mmHg155 L/min
220V50 Hz (H)0.55 kW5.3 A-740 mmHg128 L/min

Key Features of the High-Capacity VB-1400 Vacuum Pump

⚡

Performance Curve & Evacuation Planning

Review the model-specific motor and airflow data at the required voltage and frequency. Confirm flow at your working vacuum using the performance curve. Estimate evacuation time from the vessel volume, gas load, pipework and complete system performance rather than the maximum airflow or motor rating alone.

🌿

Dry Operation & Process Compatibility

Dry piston operation alone does not establish contamination-free performance or suitability for laboratory, food or pharmaceutical processes. Confirm materials, inlet filtration, exhaust arrangements, air-quality criteria and application-specific validation with the equipment integrator.

🌡️

Cooling & Duty-Cycle Requirements

Confirm cooling clearance, ambient limits, thermal protector trip and reset behaviour, and restart controls for the selected configuration. Review continuous-duty capability against the motor rating and proposed installation conditions.

🔇

Noise Data & Vibration Mounting

Confirm the noise rating, measurement distance, operating load and installation conditions for the quoted configuration. Review vibration mounting, silencing and the accessories included against the equipment and workplace requirements.

Target Industrial & OEM Applications

🪵 Woodworking & Edge-Banding Machines

For edge-banding, suction cups or clamping tables, define workpiece leakage, holding force and cycle time. Confirm flow at the operating vacuum and review filtration, controls and holding requirements in the complete machine.

🧪 Multi-Branch Lab Filtration & Rotary Evaporators

For multiple laboratory branches, provide the combined gas load, branch pressures and simultaneous-use schedule. Confirm available flow, pressure control, gas compatibility and inlet or condensation protection for the proposed system.

💊 Pharmaceutical & Food Packaging

For packaging and handling equipment, define process pressure, evacuation time, gas composition and duty cycle. Review materials, filtration, exhaust arrangements and food or pharmaceutical validation requirements with the integrator.

🏥 Hospital Central Negative Pressure Systems

For medical suction or waste-collection equipment, assess required pressure, flow, filtration, collection and equipment validation with the integrator. Review system capacity, redundancy and protective controls before selecting a pump for primary or backup duty.

Technical & Application FAQ

What are the primary performance advantages of the VB-1400 compared to lower displacement models like the VB-1200?

Compare VB-1400 and VB-1200 using performance curves at the same voltage, frequency and working vacuum. Maximum airflow differences do not establish an equivalent change in evacuation time. Review vessel volume, gas load, pipework and simultaneous-use requirements for the complete system.

How does the motor power requirement vary between VB-1400V and VB-1400H under 110V vs 220V power grids?

Review the voltage, frequency, motor rating and current for the exact VB-1400V or VB-1400H configuration in the specification table and quotation. Confirm airflow at the working vacuum and the electrical supply requirements. Listed motor ratings do not establish energy consumption under every operating load.

Is the VB-1400 engineered for high-duty cycle industrial machinery like automated edge-banders?

Confirm the permitted duty cycle and ambient limits from the selected motor rating and operating instructions. Review cooling clearance, enclosure ventilation, thermal protector behaviour and machine controls for the proposed load. Oil-free operation does not remove inspection and maintenance requirements.

How often should intake filters and piston cup seals be inspected on the VB-1400 under continuous load?

Request inspection and replacement intervals for the exact inlet filter and piston seal configuration. Review gas conditions, particle load, working vacuum, temperature and operating schedule with the supplier. Do not assume a universal filter interval or fixed piston seal service life.

Ready to Upgrade Your Industrial Vacuum System?

Send the model, target pressure, gas load, electrical supply and operating schedule for a configuration and quotation review. Request drawings and confirm availability and lead time for the proposed configuration.

Copyright © 2026 goflexpump.com. All Rights Reserved
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram