Confirm the permitted water-vapor load and gas-ballast configuration for the supplied pump. Review gas temperature, inlet pressure, operating schedule, oil compatibility and any upstream condensation or separation requirements; adding a gas ballast or condenser alone does not guarantee protection against oil emulsification.
V-020 Rotary Vane Vacuum Pump
Send the application, chamber volume, target pressure, gas composition and operating schedule. For packaging, thermoforming or resin degassing, include vapour and particle loads so inlet protection, exhaust treatment and oil requirements can be reviewed. Confirm cooling, maintenance and continuous-duty capability for the proposed installation.
Browse all rotary vane vacuum pumps to compare other models.

Image Gallery



| Parameter / Specification | Value / Detail | Key Benefit / Description |
|---|---|---|
| Model | V020 | V-Series single-stage rotary vane model |
| Pumping Speed | 20 m³/h | Confirm the pumping-speed curve at the required inlet pressure and supply frequency. |
| Ultimate Vacuum | ≤ 0.5 mbar | Confirm test conditions and the achievable system pressure under the process gas load. |
| Motor Power | 0.75 kW | Confirm the selected motor, supply frequency and power requirements. |
| Nominal Speed | 2880 rpm | Confirm the rated speed and supply frequency for the selected motor. |
| Rated Voltage | 220 V | Confirm phase, frequency and starting requirements for the supplied motor. |
| Inlet Port Size | G 3/4" Thread | Confirm thread details and mating-pipe dimensions before connection. |
| Oil Capacity | 0.5 L | Confirm the specified oil grade, filling procedure and maintenance intervals. |
| Noise Level | ≤ 62 dB(A) | Confirm noise test conditions, mounting and any installation-specific acoustic measures. |
| Net Weight | 18 kg | Plan handling and lifting using the supplied installation instructions. |
| Dimensions (L × W × H) | 320 × 230 × 215 mm | Confirm mounting points, ventilation clearances and service access before integration. |
Features & Benefits
OEM Installation Review: The page lists an 18 kg pump weight. Confirm dimensions, mounting points, ventilation space and service access against the selected configuration before integration.
Oil Mist Filtration: Confirm the supplied exhaust oil mist filter and its maintenance requirements. Exhaust quality depends on gas load, oil condition and filter condition; assess ventilation and discharge routing for the installation.
Noise & Vibration Conditions: Confirm noise test conditions and mounting requirements for the supplied configuration. Review vibration isolation and fastening against the installation instructions and supporting structure.
Continuous-Duty Conditions: Confirm the permitted duty cycle, inlet-pressure range, gas compatibility, ambient conditions and cooling requirements before specifying continuous operation.
Maintenance Access: Confirm the oil grade, inspection and replacement intervals, filter servicing and access requirements in the supplied maintenance instructions.
Target Applications & Industry Uses
Primary Industrial Applications
- Thermoforming & Packaging For blister forming or vacuum sealing, size against chamber volume, cycle time, target pressure and leakage. Confirm inlet protection, exhaust routing and any food-process contamination controls.
- Degassing & Impregnation For resin degassing, impregnation or drying, assess gas release, condensable load and required pressure. Confirm oil compatibility, gas-ballast configuration and upstream separation for the process.
- Automation & Handling For suction cups or vacuum fixtures, calculate holding force from pressure differential and effective area, then assess leakage, workpiece porosity, cycle time and loss-of-vacuum safeguards.
Equipment & System Integration
- For mold cavity evacuation, confirm cavity volume, evacuation time, target pressure and protection against particles or process carryover.
- For drying or filtration systems, confirm gas and vapor loads, operating pressure, upstream separation and the permitted duty cycle.
- For mobile or central laboratory systems, review simultaneous demand, pipeline pressure losses, gas compatibility, ventilation and maintenance access before selection.
Frequently Asked Questions
Is the V020 vacuum pump suitable for pumping gases with moisture or water vapor?
Does the V020 pump require anchor bolts or specialized vibration pads during installation?
Follow the supplied installation instructions for fastening, supporting-surface strength, ventilation and vibration isolation. Confirm mounting points and any isolation pads for the machine frame and operating conditions; pump weight or a low-noise claim alone does not establish that unanchored operation is suitable.
Ready to Upgrade Your Industrial Vacuum System?
Send the model, target pressure, gas load, electrical supply and operating schedule for a configuration and quotation review. Request drawings and confirm availability and lead time for the proposed configuration.